decor-0
decor-1
Explosion-proof compact mining station SKRV-1-065-11V
Explosion-proof compact mining station SKRV-1-065-11V
LLC “Niva-Motor”
More about the company
Export sales department:

The station is designed to control the start, stop, change of rotation speed, protection against short circuit currents and overload of three-phase asynchronous electric motors with a squirrel-cage rotor of a self-propelled car, powered by a three-phase AC network with isolated neutral, in mines and mines that are hazardous for gas (methane) and dust.

Parameter name Parameter value
Rated voltage, V 1140
AC frequency, Hz 50
Rated continuous current (max.), A 96
Voltage of intrinsically safe control circuits, V 12
Range of overcurrent protection settings, A 6,3-750
Setting range In for current overload protection, A 10-63
Overload current protection response time, 6In, max, sec 5
Controlled value of insulation resistance 1140 V, kOhm 100
Controlled thermistor resistance value, kOhm 13
Type of power contactor Vacuum
Switching wear resistance of the main contacts, ON-OFF cycles:
– in category AC-3 (with In. work. = In) 3х105
– in category AC-4 (with In. work. = 0.4In) 1х105
Mechanical wear resistance of main contacts, ON-OFF cycles 1х106
Mechanical wear resistance of the disconnector, ON-OFF cycles 6300
Frequency converter:
– rated mains voltage, V 1140±15%
– output voltage, V 20-1140
– continuous mode current, A 50
– output frequency range, Hz 1 to 99
– clock speed, kHz from 1.2 to 3
– the principle of transformation MSI – vector
– permissible current overload* 80А – maximum
70А – 1 min
60А – 6 min
– braking system electric, return
of energy into the circuit
– operating temperature, not more than ˚C <60
– liquid cooling
– maximum temperature of the radiator, not more than ˚C 60
– inverter weight, kg 17
– cooling liquid Antifreeze G12
Overall dimensions of the station, mm, no more 1500х500х900
Station weight, kg, no more 920
Level and type of explosion protection IP54
Level and type of explosion protection РВ Ex db [ib Mb] I Mb
*Long-term overload current capacity depends on the cooling conditions and inverter output frequency.

 

This website uses cookies for a better user experience. By continuing to browse the pages of the site, you agree to the use of cookies