Explosion-proof thyristor-contactor starter TKPV
Explosion-proof thyristor-contactor starter TKPV
LLC “Niva-Motor”
More about the company
Export sales department:

Explosion-proof thyristor-contactor starter TKPV is designed for remote controlled start and stop, as well as overload protection of three-phase asynchronous electric motors with a squirrel-cage rotor, protection against short-circuit currents in outgoing power circuits fed from a three-phase AC network with isolated transformer neutral in mines, dangerous gas (methane) and dust.

Parameter name TKPV 1х200М TKPV 1х300М TKPV 1х400М TKPV 2х200М TKPV 2х300М TKPV 2х400М TKPV 2х200С TKPV 2х300С TKPV 2х400С
Rated voltage, V 660/1140
Rated continuous starter current, A 200 300 400 400 600 800 400 600 800
Maximum voltage of intrinsically safe control circuits Ui, V 18
Overcurrent protection setting range, A (10-1250)*
Setting range In for current overload protection, A (10-200)*
Response time of current protection against overload 6 In, sec., no more 5**
Controlled value of insulation resistance 660/1140 V, kOhm 30/100
Controlled value of insulation resistance 42 V, kOhm 4,5
Controlled resistance value of the grounding circuit, Ohm 50
Controlled thermistor resistance value (temperature protection), kOhm 13
Коммутационная способность одной силовой ветви:
– for shutdown (effective current value), A 3150
– for switching on (amplitude value of current), A 3800
Switching wear resistance of the main contacts, ON-OFF cycles:
– in the AC-3 category (with In.working = In) 3х105
– in the AC-4 category (with In.working = 0.4In) 1х105
Mechanical wear resistance, ON-OFF cycles 1х106
mechanical wear resistance of the disconnector, ON-OFF cycles 6300
Overall dimensions, mm, no more 2240х765х820 2600х765х820
Weight, kg, no more 1130 1140 1150 1540 1560 1580 1550 1570 1590
Level and type of explosion protection IP54
Level and type of explosion protection РВ Ex d [ia] I
* Setting range of current protection for one power branch when only one electric motor is connected to the power branch; when connecting two electric motors to one power branch, the maximum setting range is automatically reduced by half (625A according to item 6 and 100A according to item 7)
** Minimum response time of current protection against electric motor overload by current 6In; based on the technical characteristics of the electric motor (depending on the class of its insulating materials) it is possible in each power circuit to change from zero to maximum, but not more than 20 seconds

 